protocol for manual defibrillators

From Aaushi
Jump to navigation Jump to search

Procedure

  • turn on debrillator
  • 360 J for monophasic defibrillators
  • select 200 J for biphasic defibrillators
  • set 'lead select' switch to 'paddles' or lead 1, 2 or 3
  • apply gel to paddles or position conductor pads on chest
  • position paddles or pads sternum-apex
  • visually check monitor display & assess rhythm
  • if monitor indicates shock (VF/VT)
    • announce 'Charging defibrillator - stand clear!'
    • charge debrillator when clear
    • when charged,
      • announce
        • 'I will shock on a count of 3'
        • '1. I/m clear'
        • '2. you're clear'
        • '3. everybody's clear'
      • verify everyone clear (no one touching patient)
      • apply 25 lbs of pressure on both paddles
      • press 2 paddle discharge buttons simultaneously
  • check the monitor
    • if monitor indicates shock (VF/VT),
      • recharge defibrillator (check pulse if rhythm in question)
      • shock again (as above) at 300 J
      • repeat & reshock 360J if indicated
  • in general shock in sets of 3 without CPR or pulse checks CPR for one 1 minute, between sets of 3 shocks