multiple sleep latency test (MSLT)
Jump to navigation
Jump to search
Indications
Procedure
- sleep is measured over night.
- the following day, repeated measurements of sleep latency (time to onset of sleep) is measured at 2 hour intervals under standardized conditions
- in narcolepsy, a decreased mean sleep latency with at least 2 sleep onset REM-periods is observed
- EEG, EKG & EOG (electro-oculogram) are monitored